[root@ESX:~] MegaCli -LDInfo -Lall -a0
Adapter 0 — Virtual Drive Information:
 Virtual Drive: 0 (Target Id: 0)
 Name :
 RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
 Size : 1.818 TB
 Sector Size : 512
 Is VD emulated : Yes
 Mirror Data : 1.818 TB
 State : Degraded
 Strip Size : 64 KB
 Number Of Drives : 2
 Span Depth : 1
 Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Default Access Policy: Read/Write
 Current Access Policy: Read/Write
 Disk Cache Policy : Enabled
 Encryption Type : None
 Bad Blocks Exist: No
 Is VD Cached: No
Virtual Drive: 1 (Target Id: 1)
 Name :
 RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0
 Size : 465.25 GB
 Sector Size : 512
 Is VD emulated : No
 Parity Size : 0
 State : Optimal
 Strip Size : 64 KB
 Number Of Drives : 1
 Span Depth : 1
 Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Default Access Policy: Read/Write
 Current Access Policy: Read/Write
 Disk Cache Policy : Enabled
 Encryption Type : None
 Bad Blocks Exist: No
 Is VD Cached: No
Exit Code: 0x00
[root@ESX:~] MegaCli -PDList -aALL
Adapter #0
Enclosure Device ID: 252
 Slot Number: 1
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 1
 Enclosure position: N/A
 Device Id: 2
 WWN: 50004cf211e64111
 Sequence Number: 2
 Media Error Count: 0
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Online, Spun Up
 Device Firmware Level: 0001
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221102000000
 Connected Port Number: 1(path0)
 Inquiry Data: S38FJ9EH202657 ST2000LM003 HN-M201RAD 2BE10001
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 6.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :29C (84.20 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 6.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252
 Slot Number: 3
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 0
 Enclosure position: N/A
 Device Id: 0
 WWN: 50004cf210417020
 Sequence Number: 3
 Media Error Count: 281
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Failed
 Device Firmware Level: 0001
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221100000000
 Connected Port Number: 0(path0)
 Inquiry Data: S321J9EG800913 ST2000LM003 HN-M201RAD 2BC10001
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 3.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :31C (87.80 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 3.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
[root@ESX:~] MegaCli -PDOffline -PhysDrv[252:3] -a0
Adapter: 0: EnclId-252 SlotId-3 state changed to OffLine.
Exit Code: 0x00
ディスク交換!
[root@ESX:~] MegaCli -PDList -aALL
Adapter #0
Enclosure Device ID: 252
 Slot Number: 1
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 1
 Enclosure position: N/A
 Device Id: 2
 WWN: 50004cf211e64111
 Sequence Number: 2
 Media Error Count: 0
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Online, Spun Up
 Device Firmware Level: 0001
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221102000000
 Connected Port Number: 2(path0)
 Inquiry Data: S38FJ9EH202657 ST2000LM003 HN-M201RAD 2BE10001
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 6.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :26C (78.80 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 6.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252
 Slot Number: 3
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 0
 Enclosure position: N/A
 Device Id: 0
 WWN: 5000c500bdd16509
 Sequence Number: 1
 Media Error Count: 0
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Unconfigured(good), Spun Up
 Device Firmware Level: SDM1
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221100000000
 Connected Port Number: 0(path0)
 Inquiry Data: WDZG58B4ST2000LX001-1RG174 SDM1
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 6.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :23C (73.40 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 6.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
[root@ESX:~] MegaCli -PDGetMissing -aALL
Adapter 0 – Missing Physical drives
No. Array Row Size Expected
 0 0 0 1907200 MB
Exit Code: 0x00
[root@ESX:~] MegaCli -PDReplaceMissing -PhysDrv[252:3] -Array0 -row0 -a0
Adapter: 0: Missing PD at Array 0, Row 0 is replaced.
Exit Code: 0x00
[root@ESX:~] MegaCli -PDRbld -Start -PhysDrv[252:3] -a0
Started rebuild progress on device(Encl-252 Slot-3)
Exit Code: 0x00
[root@ESX:~] MegaCli -PDList -aALL
Adapter #0
Slot Number: 1
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 1
 Enclosure position: N/A
 Device Id: 2
 WWN: 50004cf211e64111
 Sequence Number: 2
 Media Error Count: 0
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Online, Spun Up
 Device Firmware Level: 0001
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221102000000
 Connected Port Number: 2(path0)
 Inquiry Data: S38FJ9EH202657 ST2000LM003 HN-M201RAD 2BE10001
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 6.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :28C (82.40 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 6.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252
 Slot Number: 3
 Drive’s position: DiskGroup: 0, Span: 0, Arm: 0
 Enclosure position: N/A
 Device Id: 0
 WWN: 5000c500bdd16509
 Sequence Number: 3
 Media Error Count: 0
 Other Error Count: 0
 Predictive Failure Count: 0
 Last Predictive Failure Event Seq Number: 0
 PD Type: SATA
Raw Size: 1.819 TB [0xe8e088b0 Sectors]
 Non Coerced Size: 1.818 TB [0xe8d088b0 Sectors]
 Coerced Size: 1.818 TB [0xe8d00000 Sectors]
 Sector Size: 0
 Logical Sector Size: 0
 Physical Sector Size: 0
 Firmware state: Rebuild
 Device Firmware Level: SDM1
 Shield Counter: 0
 Successful diagnostics completion on : N/A
 SAS Address(0): 0x4433221100000000
 Connected Port Number: 0(path0)
 Inquiry Data: WDZG58B4ST2000LX001-1RG174 SDM1
 FDE Capable: Not Capable
 FDE Enable: Disable
 Secured: Unsecured
 Locked: Unlocked
 Needs EKM Attention: No
 Foreign State: None
 Device Speed: 6.0Gb/s
 Link Speed: 6.0Gb/s
 Media Type: Hard Disk Device
 Drive: Not Certified
 Drive Temperature :25C (77.00 F)
 PI Eligibility: No
 Drive is formatted for PI information: No
 PI: No PI
 Port-0 :
 Port status: Active
 Port’s Linkspeed: 6.0Gb/s
 Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
[root@ESX:~] MegaCli -PDRbld -showprog -physdrv[252:3] -a0
Rebuild Progress on Device at Enclosure 252, Slot 3 Completed 0% in 2 Minutes.
Exit Code: 0x00
しばらく待って
[root@ESX:~] MegaCli -LDInfo -Lall -a0
Adapter 0 — Virtual Drive Information:
 Virtual Drive: 0 (Target Id: 0)
 Name :
 RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
 Size : 1.818 TB
 Sector Size : 512
 Is VD emulated : Yes
 Mirror Data : 1.818 TB
 State : Optimal
 Strip Size : 64 KB
 Number Of Drives : 2
 Span Depth : 1
 Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Default Access Policy: Read/Write
 Current Access Policy: Read/Write
 Disk Cache Policy : Enabled
 Encryption Type : None
 Bad Blocks Exist: No
 Is VD Cached: No
Virtual Drive: 1 (Target Id: 1)
 Name :
 RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0
 Size : 465.25 GB
 Sector Size : 512
 Is VD emulated : No
 Parity Size : 0
 State : Optimal
 Strip Size : 64 KB
 Number Of Drives : 1
 Span Depth : 1
 Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
 Default Access Policy: Read/Write
 Current Access Policy: Read/Write
 Disk Cache Policy : Enabled
 Encryption Type : None
 Bad Blocks Exist: No
 Is VD Cached: No
Exit Code: 0x00